LoginCreate Account
  • EN
  • ES
Intech Instruments Ltd

Instrumentation • Monitoring • Control

  • Home
  • About
    • About Intech
    • Distributors/Agents
    • Agencies
    • Export
  • Downloads
    • MicroScan V5.1
    • XU Software
    • uP Configure
    • Station Programmer
    • Shimaden Lite
    • Omni7
    • Remote Support
    • USB Driver Downloads
    • IOStudio 2300 Series
    • MA5 (Mobile Alarming 5)
    • Tool Box
  • Support
    • Catalogues
    • How to Order
    • Technical Support
      • Temperature Tables
      • Probe Selection
      • Cable Guide
      • Software
      • Legacy Software
      • Discontinued Products
      • Product Videos
      • Returns – GRA
  • News
  • Contact
  • CHCH: (03) 343-0646
  • AKL: (09) 827-1930
  • Automation
    • Counters/Totalisers
    • Digital Thermostat
    • Mercury Rotating Connectors
    • Proximity Sensors
      • Capacitive Proximity Sensors
      • Inductive Proximity Sensors
    • Temperature Limiter / Monitor
    • Timers
  • Controllers & Displays
    • Chart Recorders
    • Controllers
      • Analogue Controllers
      • Controller Software
      • Digital Controllers
      • Limit Controller
      • Programmable Digital Controllers
      • Refrigeration Controllers
      • Servo Controllers
    • Displays & Indicators
      • Loop Powered Displays / Indicators
      • Process Displays
      • Selector Switch
    • Weather Covers
  • Data Acquisition
    • Cloud Based Monitoring
    • Communication Converters
    • Data Loggers
      • HR Series – Stainless Steel Data Loggers
      • Installed Data Loggers
      • LCD display Data Loggers
      • Software and Accessories
    • I/O Remote Stations / PLC Multiplexers
      • 2100 Series
      • 2300 Series
      • 2400 Series
      • Minipacks
    • SCADA Software
      • MicroScan Cloud System
      • MicroScan SCADA
      • MicroScan Wireless Connections
    • Telemetry / Wireless Connections
      • Wireless Analogue Bridge Transmitters
      • Wireless Antennas
  • Environmental
    • 4~20mA Weather Sensor Transmitters
      • Air Temperature
      • Barometric Pressure
      • Humidity
      • Light Energy
      • Mounting Options
      • Rain Gauge
      • Wind Direction
      • Wind Speed
    • Complete Weather Stations
    • Environmental Monitoring Systems
    • Humidity
      • Hand-held Hygrometer
      • Humidity Transmitters
      • Wet/Dry Bulb Humidity Transmitter
  • Flow
    • Flow Instrumentation
      • Batch Controllers
      • Flow Data Loggers
      • Flow Pulse Amplifier
      • Flow Rate Displays & Totalisers
    • Flow Meters
      • Insertion Paddle Flow Meters
      • Oval Gear Flow Meters
      • Turbine Flow Meters
    • Flow Switches
      • In Line Flow Switches
      • Paddle Type Flow Switches
      • Thermal Dispersion Flow Switches
  • Level
    • Level Switches
      • Conductive
      • Float Level Switches
      • Magnetic Coupling
      • Magnetic Tracking
      • Optical
      • Rotary Paddle
      • Vibrating Fork
      • Vibrating Rod
    • Level Transmitters
      • Accessories
      • Capacitive
      • Guided Microwave
      • Hydrostatic (Submersible)
      • Hydrostatic Level And Pressure
      • Magnetostrictive
      • Non-contact Radar
      • Ultrasonic for Liquids
      • Ultrasonic for Solids
    • Water Level & Temperature Data Logger
  • pH & Conductivity
    • Conductivity
      • Conductivity Sensors
      • Conductivity Transmitters
    • pH
      • pH Controller
      • pH Data Logger
      • pH Probes
      • pH Transmitters
  • Power Control
    • Current Meters/Switches
    • Instrument Power Supplies
    • Power Transducers
      • Current Transducers
      • Watt Transducers
    • Solid State Relays
    • Thyristor Power Controllers
  • Pressure
    • Accessories
    • Barometric Pressure Sensor
    • Differential Pressure Transmitters
    • I/P Transducers
    • Pressure Data loggers
    • Pressure Switches
    • Pressure Transmitters
  • Signal Transmitters & Conditioners
    • 2 Wire Transmitters – Loop Powered
      • AC Current
      • Bridge/Strain Gauge
      • DC Signal
      • Frequency
      • Light Intensity (Lux)
      • Potentiometer
      • RTD Pt100/Pt1000
      • Thermocouple
      • Universal Input
    • 3 & 4 Wire Transmitters
      • Bridge/Strain Gauge
      • DC Signal
      • DC to Frequency
      • Frequency to DC
      • Frequency to Frequency
      • Potentiometer
      • Resistance
      • RTD Pt100 / Pt1000
      • Set Point Alarm
      • Thermocouple
      • Universal Input
    • Download Cable
    • Isolators
    • Miscellaneous Signal Instrumentation
      • Line filter
      • Over Voltage (Lightning) Protection
      • Pulse Amplification
    • Signal Generators
  • Temperature
    • Cable
    • Infrared Temperature Sensors
    • Probe Accessories
      • Barstock Thermowell
      • Compression Fittings
      • Flanges
      • Heat Transfer Paste
        • Uncategorised
      • Pockets
      • Terminal Blocks
      • Thermocouple Connectors
      • XU-Spring-Kit
    • RTD Probes
      • Food Probes
      • RTD Elements
      • RTD Probes with Leads
      • RTD Probes with Protection Head
      • Sanitary Probes
      • Screw-In Pt100 sensors with connector
      • Surface RTD Probe
      • Wall Mount RTD Probes
    • Thermocouple Probes
      • Hand Held Thermocouples
      • Thermocouples with Connectors
      • Thermocouples with Leads
      • Thermocouples with Protection Head
      • Universal Thermocouples
    • Thermometers & Temperature Indicators
      • Digital Thermometers
      • Hand-held Thermometers
      • Limit Controller
My Order0
Home | Software Installation | Station Programmer

Station Programmer

Intech Micro Remote Station Programmer Software

This software supports the programming of stations via COM/USB ports or Ethernet TCP/IP network, along with SD Memory Data Logging on the 2400-A16-SD-NET.

Intech Micro Remote Stations supported:

  • 2400-A16, 2400-A16-NET, 2400-A16-SD-NET.
  • 2100-A16, 2100-A16-NET, 2100-D, 2100-NET.
  • Z-2400-TCP (Network Device Setup – for the XPort® Ethernet converter configuration).
Installation and Operation Notes

Windows users:

  • Installation requires the user to be an administrator.
  • Desktop shortcut icon will only be installed to the currently logged on user.

If using via the XU-USB programming key (2400-A16 stations, USB programming port):

  • Ensure that the Station Programmer software is installed before plugging in the XU-USB as this ensures that the required Windows USB driver is installed first.
  • When upgrading from a previous software version – please disconnect the XU-USB before installing.
  • Plug in the XU-USB to the computer (Standard size USB port), then the 2400-A16 station. Then power up (ensure that the voltage level matches the 2400-A16 stations’ label), the 2400-A16 station.
  • In the Station Programmer software, click on the ‘Serial Connection – COM/USB’ tab, then click the ‘Auto Detect 2400 Station’ button.
  • Note: 2400-A16 stations can also be programmed via one of their Comms ports.
  • 2400-A16-NET stations: The XPort® Ethernet converter settings must be programmed via the Ethernet TCP/IP port – see below.

If using via Network (Ethernet TCP/IP) -NET stations and Z-2400-TCP:

  • Connect the 2400-A16-NET, 2100-A16-NET, 2100-NET or Z-2400-TCP to the Ethernet TCP/IP network using a standard Ethernet (Cat 5/5e/6) cable. On the 2400-A16-NET, only plug the Ethernet cable into the Ethernet Comm Port 1 (do NOT plug into the 2400-R2 port).
  • In the Station Programmer software click on the ‘Network Connection – Ethernet’ tab.
  • You will need to allow the Station Programmer software access through the Windows Firewall in order to find the XPort® Ethernet converter and set the IP address etc. When the Windows Security Alert window appears, click ‘Allow access’.
  • Factory set IP address = 192.168.1.100
  • Factory set Port = 10001
  • This software is to be installed and/or setup by the Installer with Network IT support staff. Please note that Intech will not be able to help with the setup and operation of an Ethernet TCP/IP network and assigning of IP addresses. As part of commissioning, IT support staff should assign a static IP address to each 2400-A16-NET, 2100-A16-NET, 2100-NET or Z-2400-TCP. The 2400-A16-NET, 2100-A16-NET, 2100-NET or Z-2400-TCP should be listed as part of the Ethernet system for support by the IT support staff. It is considered good practice to write the assigned IP address/port numbers onto a label and attach to the unit for easy future reference.

If programming the 2100-A16 or 2100-A16-NET for Modbus applications:

  • Leave the 2100-A16 or 2100-A16-NET in MicroScan ASCII mode (factory default). Once all channels etc are programmed, follow the steps to change over to Modbus mode.
  • Note: The 2400-A16 and 2400-A16-NET will auto-detect Modbus operation.

If using SD memory data logging with the 2400-A16-SD-NET:

  • Configure the 2400-A16-SD-NET Input Ranges etc as usual.
  • Configure the SD recording parameters.
  • Configure the Pages & Lines for all Inputs being used.
  • Initialise SD card if more than one computer is used for download.
  • Note: Using serial comms to manually download data is very slow, and is not recommended.

WARNING: Ensure that all programming is carried out BEFORE any wiring takes place!

Download Station Programmer Now [9.2MB]
XU-USB-programming-key

XU-USB Programming Key (2400-A16 Stations, USB Programming Port)

Note: 2400-A16 stations can also be programmed via one of their Comms ports.

Note: XPort® is a registered trademark of Lantronix, Inc.

View Intech Micro Station Programmer Technical Support

Primary Sidebar

Footer

Who we are

  • Products
  • About
  • Contact us

Intech Christchurch

59 Mandeville Street
Riccarton, Christchurch 8011

Phone: (03) 343 0646

Email: sales@intech.co.nz

Intech Auckland

70 Central Park Drive
Henderson, Auckland 0610

Phone: (09) 827 1930

Email: aucksales@intech.co.nz

Newsletter

Subscribe to our newsletter and get new information every month.

Copyright © 2019–2025 Intech Instruments Ltd. All rights reserved.