GP-MC – Multi Purpose Data logger
Brand: Intech
$750.00 Excl. GST
All prices are in NZ$, and GST exclusive and are subject to change without notice.
Product Details
Description
The GP-MC is a high resolution (12 bit) multi purpose data logger with eight analogue and two digital pulse inputs. It also provides a Start on Trigger input and two alarm outputs. The GP-MC can be supplied in an optional seahorse IP66 Weatherproof enclosure if required. It can be configured to accept input from a wide variety of sources including:
|
|
The GP-MC also has an internal temperature sensor for convenient logging of ambient temperature if desired.
One to Five year battery life depending on usage as below, user replaceable. Data is retained in the event of battery failure. Battery Status Monitor in Omni7 Software.
- Warning: When using the Average, Maximum or Minimum reading(s), the logger reads the attached sensor(s) every second. This will reduce battery life.
- Using the logger in temperatures below -5°C (23°F) will reduce battery life.
A DLC5USB [USB] download cable (2m) is required to connect the GP-MC to a computer.
Note: GP-MC inputs are individually configurable using Omni7. Each input requires conditioning using a ‘Probe Set’ – see example picture below:

External Power Input:
The GP-MC has an internal battery which powers the logger and probes. However, it can also be powered by an external 5V to 15V DC Plug Pack or Battery. The main reasons for using the External power input are:
- When large current draw from probes would flatten the Internal battery; and
- At very low temperature (< 10ºC) where the Internal battery voltage can drop.
- External power can also be used to run the logger while the internal battery is changed.
The Internal battery runs the logger if the External power fails. There is an External Power Status Monitor in Omni7 software.
Please note that Intech Instruments’ recommends the internal battery be left in place in case the external power supply fails. The internal battery will keep the logger going should this happen. More information below:
If the logger is run with no internal battery and the external supply fails the logger will turn off. When the external power supply is turned back on, the logger will reboot and will be in “Stopped” mode. The logger will need to be configured in “start on condition” mode and “loop” mode and the “Start Logger” button clicked to initialise the next recording cycle.
It is recommended that the internal battery is left in. No power is drawn from the internal battery unless the external supply fails and the internal battery will keep the logger running during the down time. The logger will stay on standby and start on condition even if the external supply is still down.
* Logging Thermocouple inputs with the GP-MC:
A lot of people say thermocouple to mean temperature probes, where as if the temperature range they are measuring is between -50°C and +200°C, then RTD Pt1000 is more accurate and cheaper to implement than thermocouple. The GP-MC accepts RTD Pt1000 input (with the necessary resistors). Thermocouples are ideal for high temperature ranges.
The only way that the GP-MC can accept a thermocouple signal is via an intermediary transmitter like the XU Series with an output signal of 4~20mA.mA-MC-PS input cables for each input from the XU Series transmitter(s) into the GP-MC are also required.
The Tc-HR or Tc-LCD data loggers are available for logging 1x Thermocouple input.
Technical Specs
| GP-MC Specifications | ||
| External Connectors | ||
| Type | 4 x 4way terminal block for eight analogue inputs 1 x 4way terminal block for two digital pulse inputs 1 Female 9pinD for RS232 Communications 1 x 5way terminal block for two Alarm outputs & one Trigger input 1 x 4way terminal block for RS485 interface to remote probes | |
| Eight Analogue Channels | ||
| To log any combination of | - Temperature | - Voltage (DC) |
| - Pressure | - Wind Direction | |
| - Leaf Wetness | - Solar Energy | |
| - Humidity | - Light | |
| - Current (DC) including 4~20mA | - Soil Moisture Tension | |
| One Fast Pulse Digital Channel | ||
| To Log | - Flow | - Frequency (up to 60kHz) |
| - Wind Speed | - Counter (up to 65535) | |
| One Slow Pulse Digital Channel | ||
| To Log | - Slow Counter (up to 65535) | - Rainfall |
| -Low Frequency (up to 10Hz) | -Slow Flow (up to 10 pulses per sec) | |
| Internal Temperature | ||
| Sensor Type | Thermister | |
| Linear accuracy over range | ±0.3ºC (0ºC to 70ºC) | |
| Repeatability | ±0.1ºC | |
| Long term stability | ±0.1ºC | |
| Logger | ||
| Working Temperature | -30ºC to +70ºC | |
| Storage Temperature | -30ºC to +70ºC | |
| Sampling Rate | 1 second minimum, 10 hours maximum; in 1 second intervals | |
| Storage capacity | 1,000,000 8 bit samples; 500,000 12 bit samples | |
| Alarms | Two independent Alarms | |
| Triggered on any combination of six user configurable Alarm Conditions | ||
| Two Open Collector Alarm outputs | ||
| Alarms can be visually checked using the Omni7 Software | ||
| Start Modes | Start immediately / Start on date/time / Start on Trigger (Trigger input line) / Start on Condition (Start when a selected channel meets a condition) | |
| Stop Modes | Stop when memory is full / Stop on date/time / Loop around (continues logging) | |
| Logging modes | Each channel can be set to log any combination of | |
| - Point readings | - Maximum reading | |
| - Average reading | - Minimum reading | |
| Warning: When using the Average, Maximum or Minimum reading(s), the logger reads the attached sensor(s) every second. This will reduce battery life. We recommend using External Power | ||
| Battery | One to Five year life depending on usage as above | |
| Using the logger in temperatures below -5°C (23°F) will reduce battery life | ||
| One AA 3.6V lithium cell; User Replaceable | ||
| The data is retained in the case of battery failure | ||
| Battery Status Monitor in Omni7 software | ||
| External Power Input | 5V to 15V DC Plug Pack or Battery | |
| Internal battery runs logger if External Power fails | ||
| Can be used to run logger while internal battery is charged | ||
| Used when large current draw from probes would flatten Internal Battery | ||
| Used at very low temperature (< 10ºC) where Internal Battery voltage can drop | ||
| External Power Status Monitor in Omni7 software | ||
| Download time | 16 minutes for Full Logger | 16 minutes for Full Logger |
| Case material | PVC | PVC |
| IP Rating | GP-MC for indoor use only IP54 GP-MC with Optional Weather Proof Box IP66 | |
| Weight | 200g | 200g |
| Size | 140mm X 100mm X 25mm | 140mm X 100mm X 25mm |
| A DLC5USB is required to connect the GP-MC to a computer |
Software
Learn about Omni7 Software for Data Loggers.
Download Omni7 Software for Data Loggers.
A DLC5USB [USB] download cable (2m) is required to connect the GP-MC to a computer.
Documents
Related Products
Weather Stations
Fully Assembled and Mounted Weather StationsIn stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page
Seahorse Logger Enclosure
In stock
$340.00 Excl. GST
Select options
This product has options that may be chosen on the product page
RL Series
RTD Temperature Probes with Leads (Tip rated to 260°C)In stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page
MicroScan SCADA
Data Logging and SCADA SoftwareIn stock
$0.00
Select options
This product has options that may be chosen on the product page
DLC5USB
USB Download cable for GP-MCIn stock
$135.00 Excl. GST
Select options
This product has options that may be chosen on the product page
Similar Products
Tc-HR
Thermocouple Temperature Data LoggerIn stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page
Pt-HR
External RTD Temperature Data LoggerIn stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page
mV-HR
milliVolt Data LoggerIn stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page
GP-HR
General Purpose Data loggerIn stock
$500.00 Excl. GST
Select options
This product has options that may be chosen on the product page
Tc-LCD
Thermocouple Temperature Data LoggerIn stock
$475.00 Excl. GST
Select options
This product has options that may be chosen on the product page
P-LCD
Pressure Data logger with LCD DisplayIn stock
$0.00 Excl. GST
Select options
This product has options that may be chosen on the product page