LPI-D – DC Transmitter

Brand:

$297.00 Excl. GST

Model*

DC to DC Isolating Signal Transmitter

See Installation Guide for Ordering Information.

Total: $297.00

All prices are in NZ$, and GST exclusive and are subject to change without notice.

Product Details

LPI-D Features

  • Field programmable Bi-Polar input ranges (Model P)
  • Isolated input to output 2.0kV
  • High accuracy
  • 40~200mV output test signal
  • LED indication of loop current
  • Easy to install
  • Compact DIN rail mount enclosure
  • Available standard or special calibration
  • Reverse polarity protection
  • LPI-D-F: Fixed input ranges available: 4~20mA, 0~20mA, 0~5Vdc, 1~5Vdc, 2~10Vdc, 0~10Vdc.
  • LPI-D-P: Field Programmable input ranges from 0~10mV to 150V and from 0~200uA to 100mA.

Technical Specs

TYPELPI-D
InputVoltage10mVdc to 150Vdc and Bipolar (LPI-D-P is Field Programmable)
Min Input Resistance = 200kΩ
Max Over-range = 170Vdc Continuous
Current200µAdc to 100mAdc and Bipolar (LPI-D-P is Field Programmable)
Input Resistance = 25Ω
Max Overange = 120mAdc Continuous
Damping3 Second Selectable with H1 (LPI-D-P Only)
OutputmA2 wire 4~20mA (Loop Powered)
mV Test40~200mV ±1% @ 4~20mA, Other Test Voltages Available e.g. 1~5V
Note: mV Test Increases Power Supply & Decreases Load Resistance
Power Supply8~33Vdc
Supply Voltage Sensitivity<±0.005%/V FSO
Output Load Resistance800Ω @ 24Vdc (50Ω/V Above 8Vdc)
Maximum Output CurrentLimited to <28mA
Accurate to<±0.1% FSO Typical
Linearity & Repeatability<±0.1% FSO Typical
Ambient Drift<±0.02%/C FSO Typical
Noise Immunity125dB CMRR Average (2.0kVac RMS Limit)
EMC CompliancesEmissions EN 55022-A, Immunity EN 50082-1, <1% Effect FSO Typical
Isolation Test Voltages2000Vac/dc Input to Output for 1min
Response Time200msec Typical (10 to 90% 50msec Typical)
Operating Temperature0°C~70°C
Storage Temperature-20°C~80°C
Operating Humidity5~85%RH Max, Non-Condensing
Dimensions and ConstructionL=79, W=22.5, H=85mm. Polyamide Thermoplastic Rail Mount Enclosure

Documents