LoginCreate Account
  • EN
  • ES
Intech Instruments Ltd

Instrumentation • Monitoring • Control

  • Home
  • About
    • About Intech
    • Distributors/Agents
    • Agencies
    • Export
  • Downloads
    • MicroScan V5.1
    • XU Software
    • uP Configure
    • Station Programmer
    • Shimaden Lite
    • Omni7
    • Remote Support
    • USB Driver Downloads
    • IOStudio 2300 Series
    • MA5 (Mobile Alarming 5)
    • Tool Box
  • Support
    • Catalogues
    • How to Order
    • Technical Support
      • Temperature Tables
      • Probe Selection
      • Cable Guide
      • Software
      • Legacy Software
      • Discontinued Products
      • Product Videos
      • Returns – GRA
  • News
  • Contact
  • CHCH: (03) 343-0646
  • AKL: (09) 827-1930
  • Automation
    • Counters/Totalisers
    • Digital Thermostat
    • Mercury Rotating Connectors
    • Proximity Sensors
      • Capacitive Proximity Sensors
      • Inductive Proximity Sensors
    • Temperature Limiter / Monitor
    • Timers
  • Controllers & Displays
    • Chart Recorders
    • Controllers
      • Analogue Controllers
      • Controller Software
      • Digital Controllers
      • Limit Controller
      • Programmable Digital Controllers
      • Refrigeration Controllers
      • Servo Controllers
    • Displays & Indicators
      • Loop Powered Displays / Indicators
      • Process Displays
      • Selector Switch
    • Weather Covers
  • Data Acquisition
    • Cloud Based Monitoring
    • Communication Converters
    • Data Loggers
      • HR Series – Stainless Steel Data Loggers
      • Installed Data Loggers
      • LCD display Data Loggers
      • Software and Accessories
    • I/O Remote Stations / PLC Multiplexers
      • 2100 Series
      • 2300 Series
      • 2400 Series
      • Minipacks
    • SCADA Software
      • MicroScan Cloud System
      • MicroScan SCADA
      • MicroScan Wireless Connections
    • Telemetry / Wireless Connections
      • Wireless Analogue Bridge Transmitters
      • Wireless Antennas
  • Environmental
    • 4~20mA Weather Sensor Transmitters
      • Air Temperature
      • Barometric Pressure
      • Humidity
      • Light Energy
      • Mounting Options
      • Rain Gauge
      • Wind Direction
      • Wind Speed
    • Complete Weather Stations
    • Environmental Monitoring Systems
    • Humidity
      • Hand-held Hygrometer
      • Humidity Transmitters
      • Wet/Dry Bulb Humidity Transmitter
  • Flow
    • Flow Instrumentation
      • Batch Controllers
      • Flow Data Loggers
      • Flow Pulse Amplifier
      • Flow Rate Displays & Totalisers
    • Flow Meters
      • Insertion Paddle Flow Meters
      • Oval Gear Flow Meters
      • Turbine Flow Meters
    • Flow Switches
      • In Line Flow Switches
      • Paddle Type Flow Switches
      • Thermal Dispersion Flow Switches
  • Level
    • Level Switches
      • Conductive
      • Float Level Switches
      • Magnetic Coupling
      • Magnetic Tracking
      • Optical
      • Rotary Paddle
      • Vibrating Fork
      • Vibrating Rod
    • Level Transmitters
      • Accessories
      • Capacitive
      • Guided Microwave
      • Hydrostatic (Submersible)
      • Hydrostatic Level And Pressure
      • Magnetostrictive
      • Non-contact Radar
      • Ultrasonic for Liquids
      • Ultrasonic for Solids
    • Water Level & Temperature Data Logger
  • pH & Conductivity
    • Conductivity
      • Conductivity Sensors
      • Conductivity Transmitters
    • pH
      • pH Controller
      • pH Data Logger
      • pH Probes
      • pH Transmitters
  • Power Control
    • Current Meters/Switches
    • Instrument Power Supplies
    • Power Transducers
      • Current Transducers
      • Watt Transducers
    • Solid State Relays
    • Thyristor Power Controllers
  • Pressure
    • Accessories
    • Barometric Pressure Sensor
    • Differential Pressure Transmitters
    • I/P Transducers
    • Pressure Data loggers
    • Pressure Switches
    • Pressure Transmitters
  • Signal Transmitters & Conditioners
    • 2 Wire Transmitters – Loop Powered
      • AC Current
      • Bridge/Strain Gauge
      • DC Signal
      • Frequency
      • Light Intensity (Lux)
      • Potentiometer
      • RTD Pt100/Pt1000
      • Thermocouple
      • Universal Input
    • 3 & 4 Wire Transmitters
      • Bridge/Strain Gauge
      • DC Signal
      • DC to Frequency
      • Frequency to DC
      • Frequency to Frequency
      • Potentiometer
      • Resistance
      • RTD Pt100 / Pt1000
      • Set Point Alarm
      • Thermocouple
      • Universal Input
    • Download Cable
    • Isolators
    • Miscellaneous Signal Instrumentation
      • Line filter
      • Over Voltage (Lightning) Protection
      • Pulse Amplification
    • Signal Generators
  • Temperature
    • Cable
    • Infrared Temperature Sensors
    • Probe Accessories
      • Barstock Thermowell
      • Compression Fittings
      • Flanges
      • Heat Transfer Paste
        • Uncategorised
      • Pockets
      • Terminal Blocks
      • Thermocouple Connectors
      • XU-Spring-Kit
    • RTD Probes
      • Food Probes
      • RTD Elements
      • RTD Probes with Leads
      • RTD Probes with Protection Head
      • Sanitary Probes
      • Screw-In Pt100 sensors with connector
      • Surface RTD Probe
      • Wall Mount RTD Probes
    • Thermocouple Probes
      • Hand Held Thermocouples
      • Thermocouples with Connectors
      • Thermocouples with Leads
      • Thermocouples with Protection Head
      • Universal Thermocouples
    • Thermometers & Temperature Indicators
      • Digital Thermometers
      • Hand-held Thermometers
      • Limit Controller
My Order0
Home | Support | Technical Support | Software – Technical Support | MicroScan V5 Technical Support | Modbus TCP

Modbus TCP

Configure the XPort® Ethernet converter settings:

Note: Intech Micro Station Programmer Software includes the XPort® Ethernet configuration.

Lantronix XPort® Installer Configuration:

If the Intech field device uses a Lantronix XPort® Ethernet Device Server (e.g. 2400-A16-NET, 2100-A16-NET or 2100-NET), then it will need to be configured with the appropriate settings for the intended Ethernet network.

In particular the following must be checked and changed as required:
1. IP Address
2. Subnet Mask
3. Ethernet Port

To view and change the settings on an XPort® Ethernet Device Server download, install and run the XPort® Installer software (requires Microsoft .NET 1.1).

To check if your computer already has Microsoft .NET 1.1 installed go to Control Panel > Add or Remove Programs:

For additional information on understanding IP-Address, Subnet Masks and Ethernet Ports refer to the following links as a starting point:
– Cisco
– Microsoft
– WatchGuard

For a nifty IP Address / Subnet calculator download the Network Assistant

Connect the device to the LAN and power up.
Start the XPort® Installer software and click on the “Search” button.
A list of XPort® devices found on your network should appear in the list.
By default the IP Address should be 192.168.1.100, the subnet mask should be 0.0.0.0 and the port should be 10001.

To change the IP Address, select the respective device and click on the “Assign IP” button in the button bar.
It is a good idea to set it to something other than the default to save confusion when adding a subsequent unit.
It is also good practice to tighten up on the subnet mask, for example if all devices on your network started with 192.168.1 and the IP Address was changed to 192.168.1.99 then you could set a subnet mask of 255.255.255.0.

To view the Ethernet Port setting scroll down the properties on the right hand side and the Ports Collection should be the bottom entry – click on the Ports property and a button will appear:

Click on this button and the Port Collection Editor dialogue will appear:

By default set the Local Port to:
1. 10001 for the MicroScan TCP interface
2. 502 for a typical Modbus TCP interface
Please note that the “Enable Packing” setting must be enabled for use in the XPort®, otherwise the comms to these units will not work properly:

To save changes back to the device click on the “Update” button.

When using the device on a MicroScan PLC Interface of type Modbus TCP the port can be set as required only be sure to specify the port when adding the device to the interface.

Note: XPort® is a registered trademark of Lantronix, Inc.

Primary Sidebar

Footer

Who we are

  • Products
  • About
  • Contact us

Intech Christchurch

59 Mandeville Street
Riccarton, Christchurch 8011

Phone: (03) 343 0646

Email: sales@intech.co.nz

Intech Auckland

70 Central Park Drive
Henderson, Auckland 0610

Phone: (09) 827 1930

Email: aucksales@intech.co.nz

Newsletter

Subscribe to our newsletter and get new information every month.

Copyright © 2019–2025 Intech Instruments Ltd. All rights reserved.