LoginCreate Account
  • EN
  • ES
Intech Instruments Ltd

Instrumentation • Monitoring • Control

  • Home
  • About
    • About Intech
    • Distributors
    • Agencies
    • Export
  • Downloads
    • MicroScan V5.1
    • XU Software
    • uP Configure
    • Station Programmer
    • Shimaden Lite
    • Omni7
    • Remote Support
    • USB Driver Downloads
    • IOStudio 2300 Series
    • MA5 (Mobile Alarming 5)
    • Tool Box
  • Support
    • Catalogues
    • How to Order
    • Technical Support
      • Temperature Tables
      • Probe Selection
      • Cable Guide
      • Software
      • Legacy Software
      • Discontinued Products
    • Product Videos
    • Returns – GRA
  • News
    • Newsletters
    • Blog
  • Contact
  • Wishlist
  • CHCH: (03) 343-0646
  • AKL: (09) 827-1930
  • Automation
    • Counters/Totalisers
    • Digital Thermostat
    • Mercury Rotating Connectors
    • Photo and Proximity Sensors
      • Capacitive Proximity Sensors
      • Inductive Proximity Sensors
      • Photo Sensor
    • Temperature Limiter / Monitor
    • Timers
  • Controllers & Displays
    • Controllers
      • Analogue Controllers
      • Controller Software
      • Digital Controllers
      • Limit Controller
      • Programmable Digital Controllers
      • Refrigeration Controllers
      • Servo Controllers
    • Displays & Indicators
      • Loop Powered Displays / Indicators
      • Process Displays
      • Selector Switch
    • Weather Covers
  • Data Acquisition
    • Chart Recorders
    • Cloud Based Monitoring
    • Communication Converters
    • Data Loggers
      • HR Series – Stainless Steel Data Loggers
      • Installed Data Loggers
      • LCD Series – LCD display Data Loggers
      • Software and Accessories
    • I/O Remote Stations / PLC Multiplexers
      • 2100 Series
      • 2300 Series
      • 2400 Series
      • Minipacks
    • SCADA Software
      • MicroScan Cloud System
      • MicroScan MA5 (Mobile Alarming 5)
      • MicroScan SCADA
      • MicroScan Wireless Connections
  • Environmental
    • 4~20mA Weather Sensor Transmitters
      • Air Temperature
      • Barometric Pressure
      • Humidity
      • Light Energy
      • Mounting Options
      • Rain Gauge
      • Wind Direction
      • Wind Speed
    • Complete Weather Stations
    • Environmental Monitoring Systems
    • Humidity
      • Hand-held Hygrometer
      • Humidity Transmitters
      • Wet/Dry Bulb Humidity Transmitter
  • Flow
    • Flow Instrumentation
      • Batch Controllers
      • Flow Data Loggers
      • Flow Pulse Amplifier
      • Flow Rate Displays & Totalisers
    • Flow Meters
      • Insertion Paddle Flow Meters
      • Oval Gear Flow Meters
      • Positive Displacement /Multi-pulse Flow Meters
      • Turbine Flow Meters
    • Flow Switches
      • In Line Flow Switches
      • Paddle Type Flow Switches
      • Thermal Dispersion Flow Switches
  • Level
    • Level Switches
      • Conductive
      • Float Level Switches
      • Magnetic Coupling
      • Magnetic Tracking
      • Optical
      • Rotary Paddle
      • Vibrating Fork
      • Vibrating Rod
    • Level Transmitters
      • Accessories
      • Capacitive
      • Guided Microwave
      • Hydrostatic (Submersible)
      • Hydrostatic Level And Pressure
      • Magnetostrictive
      • Non-contact Radar
      • Ultrasonic for Liquids
      • Ultrasonic for Solids
    • Water Level & Temperature Data Logger
  • pH & Conductivity
    • Conductivity
      • Conductivity Sensors
      • Conductivity Transmitters
    • pH
      • pH Controller
      • pH Data Logger
      • pH Probes
      • pH Transmitters
  • Power Control & Instrumentation
    • Digital Power Meters
      • Current Meters/Switches
      • Multifunction Power Meters
      • Voltage Meter
    • Instrument Power Supplies
    • Power Control
      • Solid State Relays
      • Thyristor Power Controllers
    • Power Transducers
      • Current Transducers
      • Frequency Transducers
      • Power Factor Transducers
      • VAR Transducers
      • Voltage Transducers
      • Watt Transducers
  • Pressure
    • Accessories
    • Barometric Pressure Sensor
    • Differential Pressure Transmitters
    • I/P Transducers
    • Pressure Data loggers
    • Pressure Switches
    • Pressure Transmitters
  • Signal Transmitters & Conditioners
    • 2 Wire Transmitters – Loop Powered
      • AC Current (DIN Rail, Split Core & Switch)
      • Bridge/Strain Gauge
      • DC Signal: mV, V & mA
      • Frequency
      • Light Intensity / Lux Transmitter
      • Potentiometer
      • Pressure
      • RTD Pt100/Pt1000
      • Thermocouple
      • Universal Input
    • 3 & 4 Wire Transmitters
      • Bridge/Strain Gauge
      • DC Signal: mV, V & mA
      • DC to Frequency
      • Frequency to DC
      • Frequency to Frequency
      • Maths Function
      • Potentiometer
      • Resistance
      • RTD Pt100 / Pt1000
      • Set Point Alarm
      • Thermocouple
      • Universal Input
    • Download Cable
    • Isolators
    • Miscellaneous Signal Instrumentation
      • Line filter
      • Over Voltage (Lightning) Protection
      • Pulse Amplification
    • Signal Generators
    • Telemetry / Wireless Connections
      • Wireless Analogue Bridge Transmitters
      • Wireless Antennas
  • Temperature
    • Cable
    • Infrared Temperature Sensors
    • Probe Accessories
      • Barstock Thermowell
      • Compression Fittings
      • Flanges
      • Heat Transfer Paste
      • Pockets
      • Thermocouple Connectors
    • RTD Probes
      • Food Probes
      • RTD Elements
      • RTD Probes with Leads
      • RTD Probes with Protection Head
      • Sanitary Probes
      • Screw-In Pt100 sensors with connector
      • Surface RTD Probe
      • Wall Mount RTD Probes
    • Temperature Limiter
    • Thermocouple Probes
      • Hand Held Thermocouples
      • Thermocouples with Connectors
      • Thermocouples with Leads
      • Thermocouples with Protection Head
      • Universal Thermocouples
    • Thermometers & Temperature Indicators
      • Digital Thermometers
      • Hand-held Thermometers
      • Solar Powered Temperature Indicators
  • Uncategorised
My Order0
Home | Products | Controllers & Displays | Displays & Indicators | Process Displays | SD16A

SD16A – Digital Indicator

The SD16A was designed for the control of temperature, humidity and other physical values of general industrial equipment.

Digital indicator of large display and multi-input (thermocouple, RTD, DC voltage) with 48 x 96 mm size, character height 20 mm.
DC current signal can be used as an external shunt resistor.
Can be used for indication and remote indication of temperature/humidity pressure.

The SD16A supports Modbus/Shimaden communication protocols.

Brand: SHIMADEN
Usually in stock
Request a quote
Scroll down for product range
  • Product Details
  • Technical Specs
  • Ordering Information
  • Software
  • Documents

Features

  • DIN Size 48 x 96 mm
  • ± 0.3% High Accuracy Indication
  • Large 20 mm bright display
    Make reading from long distance and low light location easier
  • Multi-inputs & Multi-ranges
    User selectable Thermocouple, RTD, V, mV and Current inputs
    A 250Ω resistor is required across the input terminal for 4-20mA DC
  • Inverse scaling possible
    With voltage and current input signals, normal and inverse scaling is possible.
    Additionally, normal and inverse scaling is possible for the analog output signals.
  • Dust and splash proof front panel
    Equivalent to IP66
  • Wide range of optional features
    Alarms, analog output signals and communication interface (RS-232C or RS-485: MODBUS / Shimaden) available
    Sensor power supply 24V DC available
  • A six-point selector switch, (the KR16 series), is available for combined use.
TYPE SD16A 
Display  
 • Digital display: Process value (PV) 7 segment Red LED 4 digits (H: 20mm)
 • Action display: 1 point of parameter display (SET) by green LED
: 1 point of communication display (COM) by green LED
 • Display accuracy: ±(0.3% FS+1 digit) within measuring range
: Excluding cold junction temperature compensation accuracy in the case of
thermocouple input
: ±5%FS for temperature below 400°C of thermocouple B
: When the thermocouple [T, U] indication value is 0~100°C, 0.5%FS and
when it is below -100°C, 1%FS
 • Display accuracy range: 23°C±5°C (18~28°C)
 • Display resolution: Depends on measuring range (0.001, 0.01, 0.1, 1)
 • Measured value display range: -10~110% of measuring range (Accuracy guaranteed for value is within
measuring range only)
: For R.T.D. input of -200~600°C: 210~680°C
: For thermocouple [K] input of -199.9~800°C: -273.1~900.0 °C
 • Display update cycle: 0.25~5.00 seconds configurable (0.25 seconds step)
When 0.5 second or more is set, there may occur a difference among the
displayed value, the analog output and the communication data.
Setting
 • Setting: By four (4) front key switches
 • Setting range: Same as measuring range 
 • Setting protection: Keylock ON/OFF
Input
 • Type of input: Three-type multiple input of Thermocouple, R.T.D., Voltage (mV, V)
 • Thermocouple: B, R, S, K, E, J, T, N, {U, L (DIN 43710)}, WRe5-26
Refer to measuring range code table
 • External resistance: 100Ω max.
 • Input impedance: 500KΩ max.
 • Burnout: Standard (Up-scale)
 • Cold junction temperature: ±1°C (18~28°C range)
 • Compensation accuracy: ±2°C (5~18;°C, 28~45°C range)
(±5°C to the negative side of measuring range in case of T and U input)
 • R.T.D.: JIS Pt100Ω 3-wire type
 • Amperage: Approx. 0.25mA
 • Lead wire tolerable resistance: 5Ω max. / wire (3 lead wire should have same resistance)
When the resistance value of each wire is same
0~5°: 0.05°C, 5~10°: 0.2°C, 10~20°: 0.6°C, 20~30°C: 1.4°C max
 • Voltage (mV): 0~10mV DC
 • Voltage (V): 0~5V, 1~5V, 0~10V DC
 • Input impedance: 500KΩ min.
 • Input scaling function: Scaling possible for voltage (mV, V) or current (mA) input and inverse
scaling possible.
 • Scaling range: -1999~9999 unit
 • Span: 10~10000 unit
 • Position of decimal point: 1, 0.1, 0.01, 0.001
 • Sampling cycle: 0.25 seconds
 • PV bias: -1999~2000 unit
 • PV filter: 0~100 seconds (0 = without filter)
 • Isolation: Isolated between input and analog output (sensor power supply), or
between input and communication.
Not isolated between input and system.
Alarm output (option)
 • Number of alarm points: 2a (AL1 and AL2) for both normal open and common
 • Alarm type: Selectable from combinations of the following 4 types
: Higher limit absolute value (latching function)
: Lower limit absolute value (latching function)
 • Alarm setting range: Within measuring range or within full scaling range
 • Alarm action: ON-OFF action
 • Alarm sensitivity: 1~999 unit Within measuring range
 • Alarm output / rating: Contact 1a (common) / 240V, AC1.5A (resistive load)
 • Alarm output update cycle: 0.25 seconds
Analog output (option) / Not selectable with the sensor power supply  
 • Analog output type: 0~10mV DC (output resistance: 10Ω)
: 0~10V DC (load current: 1mA max.)
: 4~20mA DC (load resistance: 300Ω max.)
 • Output resolution: Approx. 1/14000
 • Output accuracy: ±(0.3%FS + 1 digit) of display value
 • Output scaling: Within measuring range or input scaling range (inverse scaling possible)
 • Output update cycle: 0.25 seconds
Communication (option)
 • Communication type: RS-232C, RS-485
 • Communication system: Half duplex start-stop synchronized system
 • Communication speed: 1200, 2400, 4800, 9600, 19200 bps
 • Data bit length: 7 bit even parity 1 stop bit
8 bit non parity 1 stop bit
 • Data format: 7E1, 7E2, 7N1, 7N2, 8E1, 8E2, 8N1, 8N2
 • Communication address: 1~100
 • Multi-drop connection: 31 max. (with RS-485)
 • Communication delay: 1~100 milli-seconds
 • Communication protocol: Shimaden standard protocol, MODBUS ASCII, MODBUS RTU
 • Communication code: Shimaden standard protocol: ASCII
  MODBUS ASCII: ASCII
  MODBUS RTU: binary
 • Others: Start character and BCC operation method can be selected for Shimaden
standard protocol.
Sensor power supply (option)
 • Output rating: 24V±3V DC 25mA max.
 • ON/OFF: Depending upon instrument's power ON-OFF status.
 • Restrictions: Sensor power supply can't be selected when the analog output is selected.
  Sensor power supply can't be selected when the power supply 24V is selected.
Others
 • Data storage: By non volatile memory (EEPROM)
 • Ambient conditions for use
   Temperature and Humidity
: -10~50°C/90%RH max. (on condition that there is no dew condition)
 • Height: 2000m above sea level or lower
 • Installation category: Category II
 • Degree of pollution: Degree 2
 • Power supply voltage: 100~240V AC±10%, 50/60Hz
24V AC (50/60Hz) /DC±10% (option)
 • Power consumption: 11VA (100~240V AC), 7VA (24V AC), 5W (24V DC)
 • Applicable standard
Safety
: IEC61010-1, EN61010-1
 • EMC: EN61326:1997+A1:1998, A2:2001, A3:2003
  EMC testing display accuracy ±3%FS
 • Dust proof/Drip proof: IP66 (Complies with the IEC 529-IP66)
 • Insulation resistance: Between input/output terminal and power supply terminal:
500V DC 20MΩ minimum
: Between input/output terminal and protective conductor terminal
500V DC 20MΩ minimum
 • Dielectric strength: Between all input/output terminals and power terminal:
2300V AC for one minute (faradic current 1mA)
: Between power terminal and ground terminal:
1500V AC for one minute (faradic current 1mA)
 • Case material: PPO resin molding (equivalent to UL94V-1)
 • External dimensions: H48 x W96 x D110 mm
 • Mounting: Push-in panel (one-touch mount)
 • Panel thickness: 1.0~4.0 mm
 • Panel cutout: H45 x W92 mm
 • Weight: Approx. 250g
ITEM CODE  SPECIFICATIONS
1 SERIES SD16A Digital Indicator    DIN Size 48 × 96 mm
2 INPUT 4 Current (4~20mA DC)
Applied via enclosed 250Ω shunt resistor
Scaling possible (Inverse
scaling possible) (Note:1)
8 Multi input         *Thermocouple B, R, S, K, E, J, T, N,

{U, L (DIN 43710)}

*R.T.D. Pt100? / JPt100?
*Voltage (mV, V) 0~10mV DC, 0~5V DC,
0~10V DC, 1~5V DC

Value set at
K 0~1200°C when shipped
Voltage input:
Scaling possible (Inverse
scaling possible) (Note:1)
3 POWER SUPPLY 90-  100~240V AC±10% (50/60Hz)
08- 24V AC ±10% (50/60Hz) / 24V DC ±10% (Note:2)
4 ALARM OUTPUT (OPTION) 0  None
1  Individual setting, individual output 2 points (a contact)Contact capacity: 250V AC 1.5A / resistive load
5 ANALOG OUTPUT (OPTION) OR SENSOR POWER SUPPLY (Note:2) 0  None
3  0~10mV DC   Output resistance: 10Ω Scaling possible (Inversescaling possible) within ameasuring range code
4   4~20mA DC   Load resistance: 300Ω max.
6  0~10V DC    Load resistance: 1mA max
8 Sensor power supply 24V DC 25mA max. (Note:2)
6 COMMUNICATION FUNCTION (OPTION) 0 None
5 RS-485     Shimaden standard protocol/MODBUS (RTU/ASCII) communication protoco
7 RS-232C   Shimaden standard protocol/MODBUS (RTU/ASCII) communication protoco
7 REMARKS 0 Without
9 With (Please consult before ordering)

Notes:
1. Scaling range: -1999~9999 unit, Span: 10~10000 unit
2. The sensor power supply may not be used when you select the Power Supply Code 08 (24V AC/DC)

SD16A Controllers are Shimaden Lite Software Compatible – Software Available “Free”

Download Shimaden Lite Software here

  • Shimaden Digital Indicator SD16A - Instruction Manual 533.11 KB
  • Shimaden Digital Indicator SD16A - Communication Interface Instruction Manual 461.14 KB
  • Shimaden Digital Indicator SD16A - Brochure 210.99 KB

Product Range

Product Range:
CodeSpecificationsPriceQuantity
SD16A-490-0000

Current Input, 100~240Vac.

$290.00
SD16A-490-1000

Current Input, 100~240Vac, Alarms.

$350.00
SD16A-490-0400

Current Input, 100~240Vac, Retransmission 4~20mA.

$390.00
SD16A-490-1400

Current Input, 100~240Vac, Alarms, Retransmission 4~20mA.

$450.00
SD16A-408-0000

Current Input, 24Vac.

$340.00
SD16A-408-0400

Current Input, 24Vac, Retransmission 4~20mA.

$440.00
SD16A-408-1000

Current Input, 24Vac, Alarms.

$400.00
SD16A-408-1400

Current Input, 24Vac, Alarms, Retransmission 4~20mA.

$500.00
SD16A-890-0000

Multi Input, 100~240Vac.

$290.00
SD16A-808-0000

Multi Input, 24Vac.

$340.00
SD16A-890-1000

Multi Input, 100~240Vac, Alarms.

$350.00
SD16A-890-1400

Multi Input, 100~240Vac, Alarms, Retransmission 4~20mA.

$450.00
All prices are in NZ$, and GST exclusive and are subject to change without notice.

Intech Instruments Ltd are the New Zealand distributor for Shimaden products. Please contact the Shimaden distributor in your country if you require sales or service support for Shimaden products.

Product Bottom

Not sure what you need? Ask us anything!

  • (03) 343-0646Christchurch
  • (09) 827-1930Auckland
  • sales@intech.co.nz

Primary Sidebar

Footer

Who we are

  • Products
  • Support
  • About
  • Contact us

Intech Christchurch

59 Mandeville Street
Riccarton, Christchurch 8011

Phone: (03) 343 0646

Email: sales@intech.co.nz

Intech Auckland

70 Central Park Drive
Henderson, Auckland 0610

Phone: (09) 827 1930

Email: aucksales@intech.co.nz

Newsletter

Subscribe to our newsletter and get new information every month.

Copyright © 2019–2021 Intech Instruments Ltd. All rights reserved.